Repair or Replace

Heat Pump Replacement, Step by Step: A Bryant Job in University Place

Short answer. A heat pump replacement swaps the outdoor unit and, when the old indoor unit cannot be paired with the new one, the air handler too. On this University Place job Eric and Vlad covered the floors, took both old units out, set a matched Bryant Legacy 3 ton heat pump and a Bryant air handler, cut, insulated and brazed the copper line, sealed the duct joint and connected the drain. A 3 ton heat pump starts at $7,500 installed.

By Eric, HVAC Technician Reviewed by Vlad, Owner Published
New Bryant Legacy heat pump outdoor unit on a gravel bed against a wooden fence at a University Place home
The new Bryant heat pump, on its pad by the fence. Our job in University Place, WA.

Key facts

Outdoor unit
Bryant Legacy 235SAN036, 3 ton, single stage
Indoor unit
matched Bryant FHMA air handler, 36,000 BTU
Refrigerant
R-454B (Puron Advance)
Crew
Eric and Vlad
3 ton heat pump
from $7,500 installed

Prices from our published price list, valid through December 31, 2026. Your quote is itemized after a free in-home assessment.

From the vans pulling up to the finished Bryant heat pump: the old units out, the new heat pump and air handler in, the copper line brazed and the drain connected. Watch on its own page.

This is one heat pump replacement from start to finish, filmed in a University Place home in November 2026. Eric and Vlad took out an old outdoor unit and an old air handler and put in a matched pair from Bryant. Below, each step has its own short video and a photo from the same day, with what we do at that step and why.

Why both units were replaced

A split heat pump is two pieces of equipment working as one system: the outdoor unit and the indoor unit, here an air handler in the laundry room. They are designed and rated as a pair, and they have to be made for the same refrigerant.

The new outdoor unit is a Bryant Legacy 235SAN036: a 3 ton (36,000 BTU) single stage heat pump on R-454B, the refrigerant new split systems use in place of R-410A. Bryant calls it Puron Advance. An air handler built for an older refrigerant is not paired with an R-454B outdoor unit, so the old air handler came out too and a Bryant FHMA air handler sized for 36,000 BTU went in. What R-454B changes for homeowners is in our R-454B guide.

Step 1. Arriving and unloading

Video: University Place: Arriving and unloading the new unitThe boxed Bryant heat pump comes out of the van and goes to the back yard on a hand truck.Watch it on its own page
Boxed Bryant heat pump on a hand truck crossing the lawn
The new Bryant heat pump, still in its box, on the way to the back yard. Our job in University Place, WA.

Both vans park on the driveway, and the new heat pump comes off in its factory box. It stays boxed until it reaches the back yard, on a hand truck, so the coil fins and cabinet arrive the way they left the factory.

Step 2. The old outdoor unit comes out

Video: University Place: The old outdoor unit comes outThe old outdoor unit is taken apart and carried away, and the new one goes onto the pad.Watch it on its own page
Two technicians carrying the old outdoor unit away from the house
The old outdoor unit on its way out. Our job in University Place, WA.

The old outdoor unit is disconnected, taken apart where needed and carried out. The new heat pump goes onto the pad by the fence. Removal and haul-away of the old equipment are part of the job, not an extra line in the quote.

Step 3. Protecting the floors

Video: University Place: Protecting the floorsShoe covers on and drop cloths down before anything is carried through the house.Watch it on its own page
Technicians spreading a drop cloth over the living room floor before carrying equipment through
Drop cloths go down before anything is carried through the house. Our job in University Place, WA.

The old air handler had to leave through the living room. Before anything was carried inside, the crew put on shoe covers and laid drop cloths over the floor along the whole path.

Step 4. Swapping the air handler

Video: University Place: Swapping the air handlerThe old air handler comes out of the laundry room and the matched Bryant air handler goes in.Watch it on its own page
Two technicians carrying the old air handler through a living room covered with drop cloths
The old air handler leaving through the living room, over the drop cloths. Our job in University Place, WA.

The old air handler comes out of the laundry room, over the drop cloths, and the new Bryant air handler takes its place beside the water heater. An air handler can live in a laundry room as long as there is room to service it and a place for the condensate drain.

Step 5. Sealing the duct connection

Video: University Place: Sealing the duct connectionThe joint between the air handler and the duct is taped off and sealed with mastic so the air goes where it should.Watch it on its own page

Where the air handler meets the duct, the joint is taped and sealed with mastic. A leaky joint right at the air handler blows conditioned air into the closet instead of the rooms, so this small step matters for how well the new system heats and cools.

Step 6. Cutting, insulating and brazing the line

Video: University Place: Cutting, insulating and brazing the lineThe copper refrigerant line is cut to length, insulated and brazed at the connection.Watch it on its own page
Technician brazing the copper refrigerant line at the new air handler
Brazing the copper line at the new air handler. Our job in University Place, WA.

The copper refrigerant line is cut to length, insulated and brazed at the connection to the new air handler. Brazing joins the copper with a torch and filler metal, which gives a sealed joint for the refrigerant.

Step 7. Drain and panels

Video: University Place: Drain and panelsThe PVC condensate drain gets connected and the air handler panels go back on.Watch it on its own page

An air handler makes water when it cools: moisture from the air collects on the coil. The PVC condensate drain carries it away, and then the air handler panels go back on.

Step 8. The finished system

Video: University Place: The finished systemThe new Bryant heat pump by the fence and the matched air handler with its R-454B label.Watch it on its own page
New Bryant air handler in a laundry room with an R-454B refrigerant label, insulated suction line and PVC condensate drain
The matched Bryant air handler. The label at the bottom says R-454B. Our job in University Place, WA.

Outside, the new Bryant heat pump stands on its pad by the fence. Inside, the matched air handler carries its R-454B label at the bottom, with the insulated line and the white PVC drain connected. More photos from this job are on the University Place page, and other Bryant installs are on our Bryant page.

What a replacement like this costs

Every quote is built from the same published price list:

Heat pumpStarting price, installed
2 ton$7,200
3 ton, like this job$7,500
4 ton$7,540
5 ton$7,580

A replacement usually reuses the electrical circuit and the outdoor pad. A first heat pump in a home that never had one adds a 240V circuit ($1,400) and a pad ($150). The size of your home and any upgrades are separate lines in the quote. How these lines add up, with worked examples, is in what a heat pump costs in 2026.

See your price range

Book an assessment

The in-home assessment is free: we look at the outdoor unit, the indoor unit and the space around them, and give you an itemized quote before any work starts. Book a visit or call +1 (253) 553-9579.

FAQ

Do you replace the air handler together with the heat pump?

When the old indoor unit cannot be paired with the new outdoor unit, yes. On this job the new heat pump runs on R-454B, so a matched Bryant air handler made for it replaced the old one.

Will you protect my floors?

Yes. Shoe covers go on and drop cloths go down along the path before any equipment is carried through the house, as the video shows.

Who did this job?

Eric, our HVAC technician, and Vlad, the owner. EverHeat is the two of them.

Does a heat pump replacement in University Place need a permit?

Yes. We file the mechanical permit with the City of University Place and the electrical permit with Washington L&I.

How much does a 3 ton heat pump replacement cost?

A 3 ton heat pump starts at $7,500 installed. The size of your home and any upgrades are listed separately in the quote, and the assessment is free.

Related: University Place job · Bryant · Heat pumps · How we work · R-454B refrigerant · Heat pump cost

About the author: Eric, HVAC Technician
Eric is our HVAC technician. In customer reviews he comes up most for diagnostics, replacements and heat pumps. Reviewed by Vlad, Owner.

What changed: November 23, 2026: Published.

More guides like this

Get Started

Book Your Free In-Home Assessment

Tell us what your system is doing and we will set up a visit. The assessment and the diagnostic visit are free.

Prefer to talk? Call or text +1 (253) 553-9579, Monday to Saturday, 8:00 AM to 6:00 PM.

An email works too, if that's easier. We'll reply the same way.